WEATHER PROTECTION · OP-R1—OP-R5

Five roof systems. One project-led decision.

From open-sided canopies to retractable structures on ground rails or permanent elevated frames. Compare coverage, operation and reference specifications before discussing your project.

01 · ROOF SYSTEMS

Five formats. Five distinct roles.

Choose by court count, climate, ventilation, structural height and whether you need a fully open sky.

OP-R1 Canopy Roof
OP-R1 · Open-sided overhead protection

Canopy Roof

Open-sided fixed canopy with an 11.5 × 21.5 m reference structure around a 10 × 20 m court.

COVERAGERoof membrane · open perimeter
OPERATIONFixed

Reference view; final design subject to approval

View specifications →
OP-R2 Semi-Enclosed Roof
OP-R2 · Upper-side cladding

Semi-Enclosed Roof

Fixed canopy with upper-side cladding for wind-driven rain. The lower 3 m stay open for ventilation and access; spans and heights are project-specific.

COVERAGEUpper cladding · lower 3 m open
OPERATIONFixed

Reference view; final design subject to approval

View specifications →
OP-R3 Fully-Enclosed Roof
OP-R3 · Fully enclosed multi-court

Fully-Enclosed Roof

Fixed enclosed multi-court system with opaque roof membrane and PVC zip-closure lower panels; optional HVAC requires a separate design.

COVERAGERoof and full perimeter enclosure
OPERATIONFixed

Reference view; final design subject to approval

View specifications →
OP-R4 Ground-Mounted Retractable Roof
OP-R4 · Ground-mounted retractable

Ground-Mounted Retractable Roof

Entire canopy moves on ground-level rails to expose the court. Open front and lower sides; reference maximum height 9 m.

COVERAGEOpen front and lower sides
OPERATIONRetractable: entire frame moves

Reference view; final design subject to approval

View specifications →
OP-R5 Elevated Retractable Roof
OP-R5 · Elevated folding roof

Elevated Retractable Roof

Permanent elevated frame with folding overhead membrane. Starting height 9 m, with project-assessed options up to 15 m and optional side enclosures.

COVERAGEFolding membrane on permanent elevated frame
OPERATIONRetractable: overhead membrane folds

Reference view; final design subject to approval

View specifications →
02 · SIDE BY SIDE

Compare all five formats.

Supplier reference values; structural engineering, approvals, loads and operating limits are defined for each site.

RoofOP-R1Canopy RoofOP-R2Semi-Enclosed RoofOP-R3Fully-Enclosed RoofOP-R4Ground-Mounted Retractable RoofOP-R5Elevated Retractable Roof
ApplicationIndividual courts and venues needing overhead coverage and an open perimeter.Venues requiring more side-rain screening while retaining natural ventilation.Multi-court venues needing a more sheltered indoor environment.Multi-court venues requiring open-air flexibility by moving the whole structure.Venues requiring open-sky play without moving the supporting frame.
COVERAGERoof membrane · open perimeterUpper cladding · lower 3 m openRoof and full perimeter enclosureOpen front and lower sidesFolding membrane on permanent elevated frame
OPERATIONFixedFixedFixedRetractable: entire frame movesRetractable: overhead membrane folds
HEIGHT6 m eaves · 8.5 m ridgeProject-specificSite-engineeredUp to 9 m reference maximum9 m starting · up to 15 m subject to review
StructureFixed open-sided frameFixed frame with upper-side claddingFixed full enclosureComplete moving frame on ground railsPermanent elevated frame
Membrane750 g/m² double-sided blackout PVC750 g/m² double-sided blackout PVCDouble-sided opaque PVC knife-coated fabricMembrane and weight project-specificOverhead folding membrane, project-specific
Recommended court countFrom 1; layout to confirmFrom 1; layout to confirm2+ recommended2+ recommendedFrom 1; layout to confirm

Supplier starting prices are not KND quotations and wind design targets are not structural guarantees.

03 · HOW TO CHOOSE

Which roof fits your venue?

01 · Single court

OP-R1 is a straightforward start when you need overhead sun and rain protection without perimeter walls.

02 · Partially or fully enclosed

OP-R2 keeps the lower three metres open; OP-R3 provides a multi-court enclosed venue envelope.

03 · Retractable

OP-R4 moves the entire frame along ground rails; OP-R5 keeps the elevated support in place and folds the roof above.

04 · FAQ

Before choosing a roof.

What is the difference between column and total height?

Column or eaves height is the support level, while ridge height can be higher. They affect clearance and design loads differently.

Do I need one roof for each court?

Not necessarily. R1 is a single-court reference; R3, R4 and other formats can be configured for multi-court layouts.

Are wind figures safe operating limits?

No. Supplier design targets are not instructions on when to move a roof. The responsible engineer must define operating limits and procedures.

Are transport, foundations and installation included?

These items depend on the written KND quotation and agreed project responsibilities. Never assume they are included.

05 · PROJECT BRIEF

A roof starts with your drawings.

The engineering starts with the real site. Share at least the following three sets of inputs.

01

Site and layout

Country, city, court count, available area, drawings and required clearances.

02

Local conditions

Climate, wind, rain, snow where relevant, building rules and foundation conditions.

03

Operating plan

Fixed or retractable, desired enclosure, airflow, access and project timeline.

The right roof is designed for the actual site.

Share your dimensions, location and venue brief. We will establish a technical starting point and the information needed for a proposal.

WhatsApp