OP-R4 · ROOF SYSTEM

Ground-Mounted Retractable Roof

Entire canopy moves on ground-level rails to expose the court. Open front and lower sides; reference maximum height 9 m.

View specifications ↓
OP-R4 Ground-Mounted Retractable RoofReference render; design and engineering subject to confirmation.
01 · APPLICATION

A roof starts with the actual site.

Multi-court venues requiring open-air flexibility by moving the whole structure.

Application
Multi-court venues requiring open-air flexibility by moving the whole structure.
Coverage
Open front and lower sides
Operation
Retractable: entire frame moves
02 · DIFFERENTIATORS

What makes this format different.

01

Open sky

The entire canopy rolls away on ground tracks.

02

Access and ventilation

Front and lower perimeter stay open.

03

Site-specific engineering

Rails, anchors, movement and safety depend on site engineering.

03 · VIEW SPECIFICATIONS

Reference technical specifications.

Entire canopy moves on ground-level rails to expose the court. Open front and lower sides; reference maximum height 9 m.

Application
Recommended for two or more courts
Support
Ground-mounted moving frame on rails
Open perimeter
Open front and lower sides
Upper-side fascia
High membrane fascia moving with frame
Reference maximum height
9 m
Wind design target — open
62–74 km/h, design target, NOT operating limit
Wind design target — closed
118–133 km/h, design target, NOT operating limit
Drive and controls
Project-specific
Finish and membrane
Project-specific

Reference technical data, not a structural warranty or safe operating limits. Heights, wind, loads, foundations, anchors, access and permits require project-specific engineering before supply is confirmed.

04 · SITE PLANNING

A roof starts with your site plan.

01

Site and layout

City, court count, dimensions, site drawings and working clearances.

02

Climate and standards

Wind, rain, snow when relevant, foundations and local building rules.

03

Operation and timing

Fixed or moving roof, venue requirements and intended schedule.

05 · FAQ

Before requesting a proposal.

Are the heights and dimensions final?

No. These are supplier references. The site engineer verifies dimensions, loads, clearances, columns and foundations.

What is included in the quote?

KND defines scope for the country, chosen system, dimensions, logistics and installation where applicable. Supplier starting prices are not KND prices.

What details do you need?

City, court count, site plan, dimensions, local weather, enclosure requirements and approximate schedule.

What do wind figures mean for retractable roofs?

They are supplier design targets, not safe operating wind limits or certifications. Safe operation and final capacity require site-specific engineering.

PROJECT PROPOSAL

The right roof is defined around your project.

Share the site, court count, drawings and weather-protection needs. We will review suitability before preparing a project proposal.

WhatsApp