OP-R1 · ROOF SYSTEM

Canopy Roof

Open-sided fixed canopy with an 11.5 × 21.5 m reference structure around a 10 × 20 m court.

View specifications ↓
OP-R1 Canopy RoofReference render; design and engineering subject to confirmation.
01 · APPLICATION

A roof starts with the actual site.

Individual courts and venues needing overhead coverage and an open perimeter.

Application
Individual courts and venues needing overhead coverage and an open perimeter.
Coverage
Roof membrane · open perimeter
Operation
Fixed
02 · DIFFERENTIATORS

What makes this format different.

01

Open perimeter

Open views and natural airflow around the court.

02

Defined starting geometry

Defined reference footprint for a regulation-size court.

03

Adaptable protection

Finishing options suited to the site.

03 · VIEW SPECIFICATIONS

Reference technical specifications.

Open-sided fixed canopy with an 11.5 × 21.5 m reference structure around a 10 × 20 m court.

Reference court
10 × 20 m
Structure footprint
11.5 × 21.5 m
Eaves height
6 m
Ridge height
8.5 m
Membrane
750 g/m² double-sided blackout PVC-coated membrane
Hardware
AISI 304 stainless-steel bolts and chemical anchors
Surface treatment
Zinc-rich powder coating; optional hot-dip galvanizing

Reference technical data, not a structural warranty or safe operating limits. Heights, wind, loads, foundations, anchors, access and permits require project-specific engineering before supply is confirmed.

04 · SITE PLANNING

A roof starts with your site plan.

01

Site and layout

City, court count, dimensions, site drawings and working clearances.

02

Climate and standards

Wind, rain, snow when relevant, foundations and local building rules.

03

Operation and timing

Fixed or moving roof, venue requirements and intended schedule.

05 · FAQ

Before requesting a proposal.

Are the heights and dimensions final?

No. These are supplier references. The site engineer verifies dimensions, loads, clearances, columns and foundations.

What is included in the quote?

KND defines scope for the country, chosen system, dimensions, logistics and installation where applicable. Supplier starting prices are not KND prices.

What details do you need?

City, court count, site plan, dimensions, local weather, enclosure requirements and approximate schedule.

What do wind figures mean for retractable roofs?

They are supplier design targets, not safe operating wind limits or certifications. Safe operation and final capacity require site-specific engineering.

PROJECT PROPOSAL

The right roof is defined around your project.

Share the site, court count, drawings and weather-protection needs. We will review suitability before preparing a project proposal.

WhatsApp