OP-R2 · ROOF SYSTEM

Semi-Enclosed Roof

Fixed canopy with upper-side cladding for wind-driven rain. The lower 3 m stay open for ventilation and access; spans and heights are project-specific.

View specifications ↓
OP-R2 Semi-Enclosed RoofReference render; design and engineering subject to confirmation.
01 · APPLICATION

A roof starts with the actual site.

Venues requiring more side-rain screening while retaining natural ventilation.

Application
Venues requiring more side-rain screening while retaining natural ventilation.
Coverage
Upper cladding · lower 3 m open
Operation
Fixed
02 · DIFFERENTIATORS

What makes this format different.

01

Side-rain protection

Upper cladding helps screen wind-driven rain.

02

Natural ventilation

The lower three metres remain open.

03

Site-specific design

Dimensions are specified from the court layout.

03 · VIEW SPECIFICATIONS

Reference technical specifications.

Fixed canopy with upper-side cladding for wind-driven rain. The lower 3 m stay open for ventilation and access; spans and heights are project-specific.

Span and length
Project-specific court layout
Ridge and eaves height
Confirmed by project design
Side enclosure
Fixed upper cladding, lower 3 m open
Ventilation
Natural through open lower perimeter
Membrane
750 g/m² double-sided blackout PVC-coated membrane
Hardware
AISI 304 stainless-steel bolts and chemical anchors
Surface treatment
Zinc-rich powder coating; optional hot-dip galvanizing

Reference technical data, not a structural warranty or safe operating limits. Heights, wind, loads, foundations, anchors, access and permits require project-specific engineering before supply is confirmed.

04 · SITE PLANNING

A roof starts with your site plan.

01

Site and layout

City, court count, dimensions, site drawings and working clearances.

02

Climate and standards

Wind, rain, snow when relevant, foundations and local building rules.

03

Operation and timing

Fixed or moving roof, venue requirements and intended schedule.

05 · FAQ

Before requesting a proposal.

Are the heights and dimensions final?

No. These are supplier references. The site engineer verifies dimensions, loads, clearances, columns and foundations.

What is included in the quote?

KND defines scope for the country, chosen system, dimensions, logistics and installation where applicable. Supplier starting prices are not KND prices.

What details do you need?

City, court count, site plan, dimensions, local weather, enclosure requirements and approximate schedule.

What do wind figures mean for retractable roofs?

They are supplier design targets, not safe operating wind limits or certifications. Safe operation and final capacity require site-specific engineering.

PROJECT PROPOSAL

The right roof is defined around your project.

Share the site, court count, drawings and weather-protection needs. We will review suitability before preparing a project proposal.

WhatsApp